Brand Name : IFM
Model Number : TA2532
Certification : 3C
Place of Origin : GERMANY
MOQ : 1
Price : 140$/piece
Payment Terms : T/T
Supply Ability : 1piece in stock
Delivery Time : 3 day
Packaging Details : 110*60*60mm
Measuring element : 1 x Pt 1000; (to DIN EN 60751, class A)
Probe length L[mm] : 100
Weight[g] : 231.5
Dimensions[mm] : Ø 18.7 / L = 198.8
| Product characteristics | |||||||||
| Number of inputs and outputs | Number of analogue outputs: 1 | ||||||||
| Measuring range | [°C] | -50...200 | |||||||
| Communication interface | IO-Link | ||||||||
| Process connection | threaded connection G 1/2 external thread sealing cone | ||||||||
| Installation length EL | [mm] | 100 | |||||||
| Application | |||||||||
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) | ||||||||
| Media | liquids and gases | ||||||||
| Pressure rating | [bar] | 160 | |||||||
| Pressure rating | [MPa] | 16 | |||||||
| Vacuum resistance | [mbar] | -1000 | |||||||
| Vacuum resistance | [MPa] | -0.1 | |||||||
| MAWP (for applications [bar] | 160 | ||||||||
| according to CRN) | |||||||||
| Electrical data | |||||||||
| Operating voltage | [V] | 18...32 DC; ("supply class 2" tocULus) | |||||||
| Current consumption | [mA] | < 50 | |||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time | [s] | 2 | |||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of analogue outputs: 1 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 1 | ||||||||
| Output signal | analogue signal; IO-Link; (configurable) | ||||||||
| Number of analogue outputs | 1 | ||||||||
| Analogue current output | [mA] | 4...20 | |||||||
| Max. load | [Ω] | 250; ((18...19 V); 19...32 V: 300 Ω) | |||||||
| Short-circuit protection | yes | ||||||||
| Overload protection | yes | ||||||||
![]() | |||||||||
| TA2532 | |||||||||
| Temperature transmitter | |||||||||
| TA-100CLER12- - /US | |||||||||
| Measuring/setting range | |||||||||
| Probe length L [mm] | 100 | ||||||||
| Measuring range Factory setting | [°C] | -50...200 0...200 °C | |||||||
| Resolution | |||||||||
| Resolution of analogue [K] | 0.04 | ||||||||
| output | |||||||||
| Accuracy / deviations | |||||||||
| Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) | ||||||||
| Temperature coefficient [% of the span / 10 K] | 0,1; (in case of deviation from the reference condition 25 ± 5 °C) | ||||||||
| Response times | |||||||||
| Dynamic response T05 / T09 [s] | < 0,5 / < 2 | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| Operating conditions | |||||||||
| Ambient temperature | [°C] | -25...80 | |||||||
| Note on ambient temperature | at medium temperature: < 160 °C | ||||||||
| -25...60 °C | |||||||||
| at medium temperature: < 200 °C | |||||||||
| Storage temperature | [°C] | -40...100 | |||||||
| Protection | IP 67; IP 68; IP 69K | ||||||||
| Tests / approvals | |||||||||
| EMC | DIN EN 61000-6-2 | ||||||||
| DIN EN 61000-6-3 | |||||||||
| Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) | |||||||
| Vibration resistance | DIN IEC 68-2-6 | 10 g (10...2000 Hz) | |||||||
| MTTF [years] | 232 | ||||||||
| Note on approval | factory certificate available as download at www.factory-certificate.ifm | ||||||||
| UL approval | UL Approval no. | K002 | |||||||
| Mechanical data | |||||||||
| Weight [g] | 231.5 | ||||||||
| Housing | cylindrical | ||||||||
| Dimensions | [mm] | Ø 18.7 / L = 198.8 | |||||||
| Materials | stainless steel (316L/1.4404); PEI; FKM | ||||||||
| Materials (wetted parts) | stainless steel (316L/1.4404) electropolished | ||||||||
| Tightening torque [Nm] | 30...50 | ||||||||
| Process connection | threaded connection G 1/2 external thread | sealing cone | |||||||
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | ||||||||
| Probe diameter | [mm] | 6 | |||||||
| Installation length EL | [mm] | 100 | |||||||
![]() | |||||||||
| TA2532 | |||||||||
| Temperature transmitter | |||||||||
| TA-100CLER12- - /US | |||||||||
| Remarks | |||||||||
| Remarks | MS = set measuring span | ||||||||
| The values for accuracy apply to flowing water. | |||||||||
| Pack quantity | 1 pcs. | ||||||||
|
|